Technical Parameters

ZG3NE 
Medium power single phase AC output (rail mounted type)GRM1A.png
ZG3NE Series Rail Mounted AC Output Solid State RelayZG3NE series integrated radiator (no need to calculate additional heatdissipation volume)The 22.5mm width conforms to the industrial installation design, reducingthe cabinet installation space for rail installation or screw lifting eyeinstallation.


DIN Rail - Single channel AC output
Load flows: 15, 20, 30 and 35 ampsControl voltage: 4-32VDCBuilt-in RC snubber circuit and
over-voltage protection
Zero-crossing or instantaneous
conduction output
Load voltage: 24-280VC, 48-530VACHeavy industry SCR outputIP20 safe touch enclosureLED input status indication
Model composition
Product range
ZG3NE
Load phase
1A
Load voltage
2
Rated current
15
Control voltage
D
Guide rail module1A: Single-phase AC
output
2: 24-280V Ac
5: 48-530V AC
08:08 A
15:15 A
20:20 A
25:25 A
30:30 A
35:35 A
D: 04-32VDC
B: 03-15VDC
EE: 90-230VAC



Assembly Instructions
Assembly Instructions.jpg1. Position the rail to align with the top portion of the DIN rail on the back of the SSR2. Using reasonable force, push the SSR in the direction of the arrow3. To remove, place the screwdriver on the clip and swing in the direction shownWarning: Improper method of removing the product from theDIN rail may damage the locking system

Assembly Instructions
Assembly Instructions3.jpg1. When installing SSR, the center distance of the vertical holes can be adjusted +/-1.5 mm2. For proper cooling, the SSR requires air convection (such as an indoor fan).Air convection can effectively reduce SSR heat energy generated during work.When installing multiple SSR, keep the longitudinal spacing at 80mm and the lateral spacing at least 8mm.3. If air convection cannot be provided, please reduce the load current.4. Forced cooling (such as installing indoor fans and air inlets and outlets) can significantly improve thermal performance.5. The radiator temperature should not exceed 80°С тах....WARNING: Any contact with the SSR heat sink is strictly prohibited while working.

Terminals
outputIN
Terminals-output.jpgTerminals-in.jpg
Model: DBV5.5-14 / Material: CopperWiring range: 4-6mm²Implementation standard: GB/T14315-2008Model: DBV1.25-10 / Material: CopperWiring range: 0.5-2mm²Implementation standard: GBT14315-2008
Terminals-Model.jpgModel: ZB6A GRMcomes with a blank marker


Derating curveWiring diagram
    Derating curve-1.jpg Wiring diagramWiring diagram.jpg
Attention_.jpgAttention:A well ventilated working environment can effectively imrpove the working efficiency and product life of the relay

Attention
The installation, operation, maintenance and care of electrical switches should be completed by qualified personnel. We will not bear any consequences if an accident occurs due to operational problems.SSR load-side short-circuit protection must use fast fuses or fast circuit breakers. Product damage caused by short circuits will not be covered by the warranty.It is strictly forbidden to use electric screwdrivers when wiring, as this may damage the internal structure of the relay.Warning: If the heat sink of the product is hot, be sure to let the product cool before touching it. Please follow the installation instructions. Improper operation may cause serious personal injury or permanent damage to the switch.


Warning
Risk of electric shock, explosion or arc flash when installing the product!Please cut off the power before using the product.Non-compliance can result in death, serious personal injury or damage to equipment.Do not allow liquids or foreign objects to enter this product.


Size / Material
Material.jpgThe shellDIN lifting eye
PBT-GF20-V0
Flame retardant grade
cm: nickel
FV-0.jpg
Heat sink
6063A-T6
Treatment: hard anodic matte black

Performance parameters
ZG3NE-1A 215D/220D/230D
output parameter
Working voltage(47-63HZ)24-280VAC
Transient 4overvoltage800Vpk
Maximum leakage current at off state0.25mAms
Minimum when disconnected500Vμ
Maximum load current0815203035Arms
One cycle surge current170245400725725Apk
Conduct maximum pressure drop1.3Vp 
Maximum use of fusel2t12834088025202520A2s
Substrate thermal resistance0.250.250.1550.1550.155℃ W
controls parameter
Control voltage range4-32VDC
Minimum off voltage1VDC
Maximum input current2mA 
Minimum conduction current0.5mA
Nominal input impedanceCurrent Regulated
Maximum conduction time8.33ms
Maximum break time8.33ms
fundamental characteristics
work environment-20 to 80
Storage environment-40 to 100
Input to output insulation voltage4000Vrms
Bottom insulation voltage2500Vrms
Input to output maximum capacitance8pF
Guide light colorgreen
Product weight310g 
product packagingL14.8*W13.4*T2.7cm

Performance parameters
ZG3NE-1A 515D/520D/530D/535D
output parameter
Working voltage(47-63HZ)48-530VAC
Transient 4overvoltage1600Vpk
Maximum leakage current at off state0.25mAms
Minimum when disconnected500Vμ
Maximum load current15203035Arms
One cycle surge current45075010501050Apk
Conduct maximum pressure drop1.3Vp 
Maximum use of fusel2t880252055005500A2s
Substrate thermal resistance0.250.1550.1550.155℃ W
controls parameter
Control voltage range4-32VDC
Minimum off voltage1VDC
Maximum input current2mA 
Minimum conduction current0.8mA
Nominal input impedanceCurrent Regulated
Maximum conduction time8.33ms
Maximum break time8.33ms
fundamental characteristics
work environment-20 to 80
Storage environment-40 to 100
Input to output insulation voltage4000Vrms
Bottom insulation voltage2500Vrms
Input to output maximum capacitance8pF
Guide light colorgreen
Product weight310g 
product packagingL14.8*W13.4*T2.7cm

WARNING
1.Warning: Use the incorrect method to remove the product from the DIN guide may damage the locking system
2. The installation, commissioning, maintenance and maintenance of electrical switches shall be completed by qualified engineers. Q&W will not bear any consequences for accidents caused by operational problems
3.Warning: Do not use an electric screwdriver when connecting cables. It may permanently damage the wiring terminals and SSR internal structure
4.SSR load end short circuit protection must use fast fuse, product damage caused by short circuit is not within the warranty scope
5. Do not allow liquids or foreign objects to enter this product
Model comparison table
Q&WCrydomCelducAutonicsCarlo GavazziOmronFotekTHEi-Autoc
ZG3NE-1A215DCKRD2410-SRH1-1210-NG3PJ-215BSSR-K10DA-KVS240D10-LM
SRH1-1215-NG3PE-215B
ZG3NE-1A220DCKRD2420SUL942440SRH1-1220-NRJ1A23D20EG3PE-225BSSR-K20DA-KVS240D20-LM
DR2224D20USUL842070
SAL942460
SAM943460
ZG3NE-1A230DCKRD2430-SRH1-1230-NRJ1A23D30EG3PJ-225BSSR-K30DA-KVS240D30-LM
DR2224D30UG3PE-235BSSR-K40DA
ZG3NE-1A520DCKRD4810SAL961360SRH1-1410-NRGC1A60D20KKEG3PJ-515BSSR-K10DA-HGTJ480-25AKVS480D10-LM
CKRD4820SAL962360SRH1-1415-NRJ1A60D20EG3PE-515BSSR-K20DA-HGTJ600-25AKVS480D20-LM
CKRD6010SRH1-1420-NRJ1A60D20UKVS600D10-LM
CKRD6020KVS600D20-LM
DR2260D20U
ZG3NE-1A535DCKRD4830SAL963460SRH1-1430-NRJ1A60D30EG3PJ-525BSSR-K30DA-HGTJ600-35AKVS480D30-LM
CKRD6030SAL965460G3PE-525BSSR-K40DA-HGTJ600-40A-22KVS600D30-LM
DR2260D30USUL765070G3PE-535B
DR2260D35USUL865070
SUL867070
SSR models and parameters may change at any time. The model comparison in the above table
needs to be checked against each specification parameter to ensure its accuracy.



Global Freight Services
Offering a variety of options including sea, land, and air transport to ensure your products are delivered quickly and safely to destinations worldwide.
Contact Us
Email
Message
WhatsApp
18917361687
Top