Single Output DIN-Rail Switching Power Supply | |||||||||||||||
![]() | ![]() | ![]() | |||||||||||||
Dimensions:78x93x56mm | Dimensions:78x93x56mm | Dimensions:78x93x56mm | |||||||||||||
30W Single Output DIN-Rail Type | 45W Single Output DIN-Rail Type | 60W Single Output DIN-Rail Type | |||||||||||||
Model number | Output | Tol | R&N | Effi | Model number | Output | Tol | R&N | Model number | Output | Tol | R&N | Effi | ||
IDR-30-5 | 5V,0~4A | ±1% | 80mV | 74% | IDR-45-5 | 5V,0~6A | ±2% | 100mV | IDR-60-5 | 5V,0~8A | ±2% | 80mV | 76% | ||
IDR-30-12 | 12V,0.0~2.5A | ±1% | 120mV | 81% | IDR-45-12 | 12V,0.0~3.75A | ±1% | 200mV | IDR-60-12 | 12V,0.0~4.5A | ±1% | 120mV | 82% | ||
IDR-30-15 | 15V,0.0~2A | ±1% | 120mV | 82% | IDR-45-15 | 15V,0.0~3A | ±1% | 240mV | IDR-60-15 | 15V,0.0~4.0A | ±1% | 120mV | 83% | ||
IDR-30-24 | 24V,0.0~1.5A | ±1% | 150mV | 83% | IDR-45-24 | 24V,0.0~2.0A | ±1% | 480mV | IDR-60-24 | 24V,0.0~2.5A | ±1% | 150mV | 84% | ||
SPECIFICATION | |||||||||||||||
• Universal AC input/ Full range | • AC inrush current: cold start, 27A at 115VAC; 36A at 230VAC | ||||||||||||||
• Installed on DIN rail TS35/7.5 or 15 | • DC adjustment range: ± 10% rated output voltage | ||||||||||||||
• Protections: Short circuit/Over load/Over voltage | • Over-load protection:105%-150% rated output voltage | ||||||||||||||
• Approvals:CE | • Over-voltage protection: 115%~ 135%, rated output voltage | ||||||||||||||
• LED Showing the working state | • Withstand voltage: I/P-O/P:3KVAC, I/P-FG:1.5KVAC, 0/P-FG:0.5KVAC in 1 minute | ||||||||||||||
• Cooling by free air convection | • Working Temperature: -10°C ~ 60°C | ||||||||||||||
• 100% full load burn-in test | • Connection: 1/P: 2 poles O/P: Screw DIN terminal with 4 poles | ||||||||||||||
• 2-years warranty | • Weight/Packing: 0.27kg:48pcs/16.5kg/1.02CUFT | ||||||||||||||
• AC input voltage range: 85~264VAC,47-63Hz, 120~370VDC |
![]() | ![]() | |||||||||
Dimensions:65.5x125.2x100mm | Dimensions:65.5x125.2x100mm | |||||||||
75W Single Output DIN-Rail Type | 120W Single Output DIN-Rail Type | |||||||||
Model number | Output | Tol | R&N | Effi | Model number | Output | Tol | R&N | Effi | |
IDR-75-12 | 12V,0.0~6.2A | ±2% | 100mV | 76% | IDR-120-12 | 12V,0.0~10A | ±2% | 80mV | 80% | |
IDR-75-24 | 24V,0.0~3.1A | ±1% | 150mV | 80% | IDR-120-24 | 24V,0.0~5.0A | ±1% | 80mV | 84% | |
IDR-75-28 | 48V,0.0~1.5A | ±1% | 240mV | 81% | IDR-120-48 | 48V,0.0~2.5A | ±1% | 100mV | 84% | |
SPECIFICATION | SPECIFICATION | |||||||||
• AC input, selectable by switch | • AC input, selectable by switch | |||||||||
• Installed on DIN rail TS 35 /7.5 or 15 | • Installed on DIN rail TS 35 /7.5 or 15 | |||||||||
• Protections:short circuit/Overload/Over voltage/Over temp | • Protections:short circuit/Overload/Over voltage/Over temp | |||||||||
• Approvals: CE | • Approvals: CE | |||||||||
• LED Showing the working state | • LED Showing the working state | |||||||||
• Cooling by free air convection | • Cooling by free air convection | |||||||||
• 100%full load burn-in test | • 100%full load burn-in test | |||||||||
• 2-years warranty | • 2-years warranty | |||||||||
• AC input voltage range: 85~132VAC/170~264VAC selectable by switch | • AC input voltage range: 85~132VAC/170~264VAC, selectable by switch | |||||||||
• AC inrush current: Cold start, 30A at 115VAC, 60A at 230VAC | • AC inrush current: Cold start,30A at 115VAC,60A at 230VAC | |||||||||
• DC adjustment range: 12:12~14,24:24~28V,48:48-53V | • DC adjustment range: 12:12~14,24:24~28V,48:48-53V | |||||||||
• Over-load protection:105%-150% rated output voltage | • Over-load protection:105%-150% rated output voltage | |||||||||
• Over-voltage protection: 120%-140% rated output voltage | • Over-voltage protection: 120%-140% rated output voltage | |||||||||
• Withstand voltage: I/P-O/P:3KVAC, I/P-FG:1.5KVAC, 0/P-FG:0.5KVAC in 1 minute | • Withstand voltage: I/P-O/P:3KVAC, I/P-FG:1.5KVAC, 0/P-FG:0.5KVAC in 1 minute | |||||||||
• Working temperature: -10°C ~60°C | • Working temperature: -10°C ~ 60°C | |||||||||
• Connection: I/P: Screw DIN terminal with 3 poles | • Connection: I/P: Screw DIN terminal with 3 poles | |||||||||
• Weight/Packing: 0.65kg, 20PCS/13kg/1.1CUFT | • Weight/Packing: 0.7kg, 20PCS/16.5kg/1.1CUFT |
![]() | ![]() | |||||||||||
Dimensions:125.5x125.2x100mm | Dimensions: 227x125.2x100mm | |||||||||||
240W Single Output DIN-Rail Type | 480W Single Output DIN-Rail Type | |||||||||||
Model number | Output | Tol | R&N | Effi | Power | Model number | Output | Tol | R&N | Effi | Power | |
IDRP-240-24 | 24V,0.0~10.0A | ±1% | 80mV | 84% | 240W | IDRP-480-24 | 24V 0~20A | ±1% | 120mV | 89% | 480W | |
IDRP-240-48 | 48V,0.0~5.0A | ±1% | 150mV | 85% | 240W | IDRP-480-48 | 48V 0~10A | ±1% | 120mV | 89% | 480W | |
SPECIFICATION | SPECIFICATION | |||||||||||
• Universal AC input/ Full range | • Universal AC input/ Full range | |||||||||||
• Installed on DIN rail TS 35 /7.5 or 15 | • Installed on DIN rail TS 35 /7.5 or 15 | |||||||||||
• Protections: Short circuit/Overload/Over voltage/Over temp | • Protections:short circuit/Overload/Over voltage/Over temp | |||||||||||
• Built-in PFC(power factor correction) | • Approvals: CE | |||||||||||
• Approvals: CE | • LED indicating the working state | |||||||||||
• LED Showing the working state | • Cooling by free air convection | |||||||||||
• Cooling by free air convection | • 100%full load burn-in test | |||||||||||
• 100%full load burn-in test | • 2-years warranty | |||||||||||
• 2-years warranty | • AC input voltage range: 90-132VAC/180-264VAC, selectable by switch | |||||||||||
• AC input voltage range: 85-264VAC | • AC inrush current: Cold start,30A at 115VAC, 50A at 230VAC | |||||||||||
• AC inrush current: Cold start, 30A at 115VAC, 50A at 230VAC | • DC adjustment range: 24~28/48-53V | |||||||||||
• DC adjustment range: 24~28/48-53V | • Over-load protection: 105~150% shutdown current, automatically resume | |||||||||||
• Over-load protection: 105~150% shutdown current, automatically resume | • Over-voltage protection: 30~36V/54~60V for output shutdown and restart | |||||||||||
• Over-voltage protection: 30~36V/54~60V for output shutdown and restart | • Setup, rise,hold up time: 1200ms,40ms,16ms at full load and 230VAC | |||||||||||
• Setup, rise,hold up time: 800ms,40ms,20ms at full load and 230VAC | • Withstand voltage: I/P-O/P:3KVAC, I/P-FG:1.5KVAC, 0/P-FG:0.5KVAC in 1 minute | |||||||||||
• Withstand voltage: I/P-O/P:3KVAC, I/P-FG:1.5KVAC, 0/P-FG:0.5KVAC in 1 minute | • Working temperature: -20°C ~50°C | |||||||||||
• Working temperature : -10°C ~55°C | • Connection: I/P: 3 poles O/P: DIN type screw terminals with 4 poles | |||||||||||
• Connection: 1/P: 3 poles O/P: DIN type screw terminals with 4 poles | • Weight/Packing: 2.4kg, 6PCS/15kg/1.75CUFT | |||||||||||
• Weight/Packing: 1.2kg, 12pcs/15.5kg/1.2 CURT |